33kv Prefabricated Distribution Combined Substation Power Transmission/Supply Substation, Prefabricated Substation,
- Mar 11, 2018 -

Basic Info

  • Altitude: up to 1, 000m Above Sea Level

  • Special Conditions: Depends on The Customer

  • Tap Changer: Regulate The Output Voltage

  • Typical Products: Zbw

  • Warranty: 10 Years

  • Specification: IEC

  • HS Code: 8504231100

  • Transformer: Oil Transformer

  • Environment: Outdoor

  • Insulation Oil: High Quality Grade Mineral Oil

  • Test Equipment: IEC Standard

  • Frequency: 50Hz

  • Trademark: YUBIAN

  • Origin: Cn

Product Description

Substation, Prefabricated Substation, Combined Substation

 SC(B)13型环氧树脂浇注干式变压器


Service condition
1. Altitude: ≤ 1000m (above sea level)
2. Ambient temperature: Max. 40C Min. -25C
  >>Max. Monthly average temperature: ≤ 35C
  >>Max. Yearly average temperature: ≤ 25C
3. Relative humidity: Daily average value≤ 95%, monthly average value≤ 90%
4. Max. Daily difference in temperature: 25C
5. Sunlight intensity: 0.1W/CM2 (wind speed 0.5M/S);
6. Outdoor wind speed: ≤ 35m/s;
7. Pollution grade: Grade III;
8. Rain proof grade: Grade 3;
9. The gradient on installation spot shall be not more than 3° ;
10. Ability of anti-earthquake: Horizontal acceleration of ground surface is 0.2g
      Vertical acceleration of ground surface is 0.1g;
11. Installation spot: The spot should has no fire/explosion danger/serious pollution/chemical 
      corrosion and exquisite shake.
****Customer should negotiate with manufacturer if the service condition is different from above.
Our advantage
1.Various  special requirement from customer or typical specification .
2.Competitive price (Real factory ).
3.Excellent quality control.
4.Good service and after sales.
5.In time delivery.
6. Manufacturing after drawings approved.
7.OEM is acceptable.We can change the design as client's requirements.
*****More information, please freely contact us. Glad to service you.

UnitSwitch ubicleCircuit breakerItemsInData
H. V. unit  40.5kVKYN10-40.5
JYN1-40.5
ZN23-35
ZN12-35
LN2-35(Z)
Rated voltagekV40.5
Rated currentA1250-1600
Rated short-circuit breaking currentkV20-31.5
Rated short-circuit making current
(crest)
A50-80
On-load startingNAL36
NALF36
Rated currentA630
Rated short-time withstand currentkA/s25/2
L. V. unit12kVXGN56-12
XGN2-12
KZN1-12
KYN1-12
ZN28A-12
ZN28B-12
VD4
VT2-12
VT1-12
Rated voltagekV12
Rated currentA630-3150
Rated short-circuit breaking current(r. m. s)kA16-50
Rated short-circuit making current
(crest)
kA40-125
HXGN11-12
(F)
HXGN26-12 (F)
On-load starting
FN16-12
FN26-12
FN26-12R
Rated currentA630
Rated short-time withstand currentkA/s20/3, 25/2
0.4kVGGD
GCT
GCS
DW15
ME, M, F
DZ20
CM, H, S series
Rated current of circuit breakerA70-3900
Breaking capability(400V)kA28-80
Transformer unitSC9, S9, SZ9 transformerRated voltagekV40.5
Rated capabilitykVA400-20000
RatiokV / kV35/10, 35/6.3, 35/0.4